Air Circuit Breaker

Air Circuit Breaker

Detailed Air Circuit Breaker Description

GTW1 () series air circuit breakers () are used to protect the circuit from
overload, under - voltage, short - circuit and earth fault in distribution electric
net with AC50Hz, rated operation voltage 400 / 690V, rated current 400A 6300A. The key part uses intelligent release unit to ensure selective
protection ways to make the circuit release from unnecessary power - off and
high operation reliability. Frame
under 630A can be used as overload, under - voltage and short - circuit protection
for electric motors. The products conform to IEC 60947 - 2, IEC 60947 - 4
standards. Withdrawable
type is combined by contact system, manual operation
mechanism, intelligent release, electric operation mechanism and mounting board; withdrawable type
are combined by contact system, manual operation mechanism, intelligent release, 
electric operation mechanism and withdraw base. 

Normal operation and mounting requirements:
a) Altitude for installation: oC (minimum value within 
 -10 ~ -25oC applicable, >+40oC or <-25oC need
)
c) Humidity:
 1) Relative humidity of atmosphere: oC
 2) Higher relative humidity can be permitted at lower temperature
 3) Monthly average humidity is under 90% when the min. monthly
 average humidity is under +25 in the most watery month
 4) Meanwhile the coagulate water occurred on the surface of
 products should be taken into account
d) Pollution degree: 3
e) Installation category: IV; for auxiliary circuit the under - voltage
 release coil and primary coil of voltage transformer are the same
 with breaker, the others are construction features

This kind of product is divided into two types: withdrawable and fixed type.

Breakers are solid distributing. Contact
system is in the insulation bottom - board. It has compact construction and small volume. Phase - contacts are disconnected
to form a little scope. If one unit is damaged you can disassemble it to replace
for a new one. The intelligent release, manual operation mechanism and
electric operation mechanism are in the front the contact system one by one and
are independent units.

Because the product only uses one group of contacts (omit the arcing ) to
decrease operation force of contacts and accelerate the procedure of breaking,
the contact system uses parallel method to decrease electric exclusion force and
to improve the electric stability. 

The arc - damping chamber is made by insulation material. Contacts, soft connecting and bus bar all use
welding to low the touching resistance and power consumption. Contact system and arc - damping
system are placed between upper base and bottom base both of which are made
from high strength and excellent electric performance insulation materials. When
breaking short circuit current the air can only give out to the upper position
(ensure the reliability of down line - in wiring ). Each
phase is designed as independent arc - damping chamber while contacts are assembled
on the insulation brackets to prevent from phase - to - phase short circuit. 

The ACB is designed with the operating mechanism charged either manually or electrically
for closing and opening. The energy stored springs of the ACB is charged
through a cam. Its closing speed is independent of the speed of
electric and manual operation. The ACB is designed with three positions (including trip free ).

Intelligent release has such functions as below:
a) Reverse long time delay for over load protection, reverse short - time
 delay, definite short - time delay, and instantaneous for short - circuit
 protection 
b) Earth fault protection 
c) Overload alarm 
d) Test 
e) Load monitoring 
f) Functional display 
g) Diagnostic 
h) MCR 
i) Thermal memory 
j) Contact abrasion indication 
k) Fault memory

We have been a leading manufacturer and exporter of Air Circuit Breaker

Contact information:

Inquire
Address: Xinguang Industrial Zone, Yueqing, Liushi, Wenzhou City, Zhejiang Province. China
Company Name: Zhejiang Jubang Electrical Co., Ltd.
Contact Person: Frank Zhang
Fax: 86-577-62799771
Mobile Phone: 86-13757779781
Telephone: 86-577-62799786
Website: http://www.mccb.cn
Zip: 325604

Similar Products

Earth Leakage Circuit Breakers
Earth Leakage Circuit Breakers
CDM1 Molded Case Circuit Breaker ()
CDM1 Molded Case Circuit Breaker ()
Mini Circuit Breaker
Mini Circuit Breaker
Mini Circuit Breaker
Mini Circuit Breaker
Mini Circuit Breaker
Mini Circuit Breaker
Mini Crcuit Breaker
Mini Crcuit Breaker
Mini Circuit Breaker
Mini Circuit Breaker
Mini Circuit Breaker
Mini Circuit Breaker

Home - Gold Suppliers - Buy - Sell - Trade Shows - My Germes-Online - About Germes-Online - Help - Site Map - Contact Us
© 1999-2005 Germes LLC. All rights reserved.